Weight |
3 kg
weight, may vary within tolerance
|
m² Unit |
35 - 25
Need of m2 use may vary depending on the the dimensions,tolerances and thickness of the mortar used.when width of wall is 190 mm the need of use is 35 units and when the width of the wall is 135 mm the need of use is 25 units for each m2.
|
Fire Response |
A1
The Clay Products are classified as Class A1 without testing,according to the Regulations of the Fire.
|
Public Works Pos No |
04.018(C)
The number of the related product at the Unit Price List of Bayındırlık and ve İskan Bakanlığı.
|
Volume Weight |
650 kg/m3
May vary depending on the D1 tolerance related to standard of TS EN 771-1.
|
Thermal Conductivity Account Value |
0,331 W/mK
|
Loss of Sound Crossing (Rw) |
43 dB
|
Pressure Resistance |
2 N/mm2
Is used in partition walls;carrier feature is missing.
|
Size |
190 x 135 x 190
Horizontal Holed Bricks
|
Wall Thickness |
190mm – 135mm
|
Moisture Movement |
NPD
|
Bond Strength |
Sabit Değer 0,15 N/mm2
|
Water Absorption |
Açık hava koşullarına maruz bırakılmayan tip
|
Water Vapor |
9,16 m
|